TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 985 of 1632

Change 1
2-1741
TM 9-2320-366-20-2
RESISTANCE TEST
754-820 ohms
691-754 ohms
889-962 ohms
820-889 ohms
962-1039 ohms
1039-1118 ohms
1118-1202 ohms
1202-1286 ohms
122° to 140°F (50° to 60°C)
86° to 104°F (30° to 40°C)
104° to 122°F (40° to 50°C)
68° to 86°F (20° to 30°C)
50° to 68°F (10° to 20°C)
32° to 50°F (0° to 10°C)
14° to 32°F (-10° to 0°C)
-4° to 14°F (-20° to -10°C)
Temperature
Resistance
Table 2-34.
Transmission Sump Oil Temperature
Sensor Resistance Readings
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to connector P119a.
NOTE
Transmission sump oil temperature
sensor resistance reading is affected by
temperature.
Refer to Table 2-34.
Transmission Sump Oil Temperature
Sensor Resistance Readings for details.
(3)
Connect negative (-) probe of multimeter to
connector P119d and note reading on
multimeter.
(4)
Connect negative (-) probe of multimeter to
all other pins in connector P119, one at a
time, and note reading on multimeter.
(5)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6)
Connect positive (+) probe of multimeter
to connector P119d.
(7)
Connect negative (-) probe of multimeter to
all other pins in connector P119 (except
P119a), one at a time, and note reading on
multimeter.
(8)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(9)
If correct resistance is not present in step
3, or continuity is present in step 4, 5, 7,
or 8, notify DS Maintenance.
(10)
If correct resistance is present in step 3
and continuity is not present in step 4, 5,
7, or 8, replace WTEC III transmission
ECU (para 8-7).
(11)
Connect connector P119 to connector
J119.
(12)
Position front grille on cab with washer
and screw.
(13)
Position two washers and screws in front
grille.
(14)
Tighten screw to 48-60 lb-in. (5-7 N·m).
(15)
Tighten two screws to 24 lb-in. (3 N·m).
(16)
Clear diagnostic codes (para 8-5).


Back to Top