TM 9-2320-366-20-4
(7) Perform STE/ICE-R Test #50 (TM 9-4910-571-12&P).
NOTE
Turning adjustment screw to the left will
increase
wet
tank
pressure.
Turning
adjustment screw to the right will decrease
wet tank pressure.
(8) Turn adjustment screw (6) until 120-130 psi is
observed on STE/ICE-R.
(9) Tighten nut (5) on adjustment screw (6).
(10) Install cover (3) on air compressor governor (4).
(11) Lower cab (TM 9-2320-366-10-1).
(12) Shut down engine (TM 9-2320-366-10-1).
(13) Drain air tanks (TM 9-2320-366-10-1).
(14) Remove STE/ICE-R from wet tank (2).
WARNING
Adhesives,
solvents,
and
sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(15) Apply antiseize compound to threads of drain valve (1).
(16) Install drain valve (1) in wet tank (2).
Change 1