Change 1
2-113
TM 9-2320-366-34-1
RESISTANCE TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to pin 1 of turbine speed sensor.
(3)
Connect negative (-) probe of multimeter
to pin 2 of turbine speed sensor and note
reading on multimeter.
(4)
If resistance is less than 200 ohms or
greater than 400 ohms, replace turbine
speed sensor (para 6-5).
(5)
If resistance is between 200 and 400
ohms, replace WTEC II TEPSS
(TM 9-2320-366-20-4).
(6)
Connect internal wiring connector TSS
to turbine speed sensor.
(7)
Install cover on control valve module
with four screws.
(8)
Install control valve module (para 7-10).
(9)
Connect external wiring harness 24-pin
connector to internal wiring harness
24-pin connector.
(10)
Tighten screw in external wiring harness
24-pin connector.
(11)