TM 9-2320-366-34-3
16-15. M1084/M1086 PROXIMITY SENSOR REPLACEMENT (CONT)
WARNING
Adhesive-sealant MIL-S-46163 can damage
your eyes.
Wear safety goggles when
using;
avoid
contact
with
eyes.
If
adhesive-sealant
contacts
eyes,
flush
eyes
with
water
and
get
immediate
medical attention. Failure to comply may
result in injury to personnel.
(4) Apply sealing compound to threads of two screws (8).
(5) Position bracket (4) on hoist assembly (9) with two
washers (10) and screws (8).
(6) Tighten screws (8) to 72-78 lb-ft (98-106 N·m).
NOTE
Install plastic cable ties as required.
(7) Install clamp (11) on cable (12).
(8) Install clamp (11) on boom stud (13) with washer (14)
and nut (15).
(9) Connect connector (16) to overload shutdown box (17).
16-78