TM-9-2320-386-10

2-1/2-TON, 6X6, M44A3 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; EXTENDED SERVICE PROGRAM (ESP); OPERATOR’S MANUAL

JANUARY 1996

  TM-9-2320-386-10 - Page 68 of 223

Table 2-2. Operator/Crew Preventive Maintenance Checks and Services (Contd).
ITEM
NO.
INTERVAL
ITEM TO
CHECK/
SERVICE
PROCEDURE
NOT FULLY
MISSION
CAPABLE IF:
TM 9-2320-386-10
2-35
30
After
Air
Check air cleaner indicator (6) at
Yellow band is seen
Operation
cleaner
bottom of instrument panel. If yellow
on the indicator
(Contd)
indicator
band is showing after air cleaner has
with engine running
been serviced, air intake system or air
and the filter cannot
cleaner indicator tube are clogged.
be cleaned or
Notify unit maintenance.
replaced.
31
Horn
Check operation if tactical situation
permits.
32
Fuel
shutoff
switch
Move fuel shutoff switch (7) to ON
Engine does not
position to turn off fuel to the engine.
stop.
6
WARNING
If tachometer shows engine
idling at high RPM and fuel
shutoff switch does not stop
engine, do not attempt to stall
engine. Notify your supervisor.
Attempting to stall engine at
high RPM may result in injury
or death to personnel.
NOTE
If tachometer shows engine is
idling at normal RPM and battery
switch does not stop engine, engage
fuel shutoff switch to stall engine.
7