TM-9-2320-386-24-1-1

2-1/2-TON, 6X6, M44A3 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; EXTENDED SERVICE PROGRAM (ESP); UNIT, DIRECT SUPPORT AND GENERAL SUPPORT; MAINTENANCE MANUAL; VOLUME 1 OF 2

MAY 2001

  TM-9-2320-386-24-1-1 - Page 951 of 1078

REMOVAL
1.
Loosen screw (7) and remove lead (5) from receptacle (6).
NOTE
Locking hardware is provisioned with receptacle.
2.
Remove nut (3), lockwasher (4), and receptacle (6) from side panel (8).
3.
Remove twenty tiedown straps (17) from lighting harness (10) and lead 10A (9). Discard tiedown
straps (17).
4.
Disconnect plug (1) from connector (2) and remove lead (5).
5.
Disconnect plug (12) from circuit breaker (11).
6.
Remove locknut (15), screw (13), clamp (14), and lead (9) from lighting harness (10) and
support (16). Discard locknut (15).
INSTALLATION
1.
Install lead 10A (9) on lighting harness (10) with twenty new tiedown straps (17).
2.
Install lighting harness (10), lead 10A (9), and clamp (14) on support (16) with screw (13) and new
locknut (15).
3.
Connect plug (12) to circuit breaker (11).
4.
Connect plug (1) to connector (2) on lead (5).
5.
Install receptacle (6) on side panel (8) with lockwasher (4) and nut (3).
6.
Install lead (5) on receptacle (6) and tighten screw (7).
8.
Connect battery ground (GND) cable (WP 0121 00).
TM 9-2320-386-24-1-1
0263 00
SWINGFIRE HEATER WIRING HARNESS AND RECEPTACLE REPLACEMENT (Contd)
0263 00-2


Back to Top