TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 296 of 1205

REFERENCE INFORMATION
BAD CONNFCTIONS
ARF MF
MOST COMMON
PRO61 FM !
Sometimes just disconnecting,
cleaning, and reconnecting
will solve a problem.
BE THOROUGH
! The time you save
may be your own.
Refer to the functional flow schematic and check the
following:
1. BAlTERY
- make sure all connections
are clean and tight.
This includes the interconnect
cables, clamps, shunt, power
stud, and the slave connector.
Also check wires 6A and 7A
under vehicle where they enter shunt.
2. STARTER - check the high current (heavy gauge) wire at
the starter.
Don’t just check for voltage; a loose connection
will have voltage but can’t carry much current.
There is a ring inside the
battery fill plugs. The water
level should be at the ring.
BATTERIES
TM 9-2320-387-24-l
BAJTERY CIRCUIT
BATTERY
FILL PUJG
BATTERY WATER
lEvElRlNG
BATTERY
VOLTAGE
STEKE-R
TEST
67
1. Start Test 67. Battery Voltage.
2. Displayed
reading is in volts.
Batteries should
be 23-25.5 volts.
Batteries voltage will drop
when glow plugs turn on.
2-239