  TM-9-2320-387-24-1 - Page 311 of 1205

REFERENCE INFORMATION
TM 9-2320-387-24-l
STARTER CIRCUIT
Connect red to
positive = power stud.
Connect black to
negative = battery side of current shunt.
Replace batteries (para. 4-74).
i
Connect red to
positive = power stud.
Connect black to
negative = battery side of current shunt.
Replace batteries (para. 4-74).
I
BATTERY VOLTAGE
STMCE-R
TEST 67
I
1. Start Test 67, Battery Voltage.
2. Displayed
reading is in volts.
Batteries should
be 23-25.5 volts.
Batteries voltage will drop
when glow plugs turn on.
I
VOLTAGE
MULTIMETER
I
1. Set the voltmeter to a DC volts scale of at least
40 volts.
2. Connect the RED lead to positive and the
BLACK lead to negative.
3. Be sure to read the correct scale.
VOLTMETER
2-255