TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 389 of 1205

TM
9-2320-387-24-l
REFERENCE INFORMATION
-I
Replace wiper motor (para. 10-63).
INSTRUMENTS
CIRCUIT
DC VOLTAGE
O-45 VOLTS
STWICE-R
TEST 89
1. Connect RED clip to the indicated test point
BUCK
clip to negative or ground.
2. Start Test 89, DC Volts.
3. Displayed
reading is in volts.
BATTERY
VOLTAGE
MULTIMETER
1. Set the voltmeter
to a DC volts scale of at least
40 volts.
2. Connect the RED lead to positive and the
BLACK lead to negative.
3. Be
sure to read the correct scale.
RESISTANCE
AND C0NllNUll-Y
0-4,!XKl OHMS
STEllCE-R
TEST
91
1. Connect RED clip and BLACK clip to the
indicated terminals in the question. RED to the
first,
BLACK
to the second.
2. Start Test 91,045tXJ
Ohms.
3. Displayed
reading is in ohms. Less than 5
ohms is continuity.
If the resistance is over
4.606 ohms, STEACE-R displays .9.9.9.9.
CONTNUITY
(RESISTANCE)
MULTIMETER
1. Set the voltmeter
to an ohms scale of about
1 ,ooO ohms.
2. Connect the RED and BLACK leads to the
connections
stated in the question.
3. Be sure to read the correct scale. Less than 5
ohms indicates continuity.
For an open circuit,
the meter should peg full scale (needle all the
way to the left).
2-335