TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 54 of 1205

TM
9-2320-387-24-l
l-23.
BATTERY SYSTEM OPERATION
The
battery system is identical for both vehicles covered in this manual and consists of the following circuits
and components:
0
A
0
B
0
C
0
D
0
E
0
F
0
G
0
H
CIRCUIT 6A - Connects the batteries to the starter and to the protective control box through
circuit 8%
BATTERIES - Two 6TN batteries are connected to provide 24 volts DC for the electrical
starting
system.
SLAVE RECEPTACLE - Links an external power source directly to the slaved vehicle’s batteries to
assist in cranking the engine when the vehicle’s batteries are not suffkiently charged.
SHUNT - Used when measuring current draw from batteries utilizing STEACE-R.
PROTECTIVE
CONTROL BOX (PCB) - Protects the vehicle electrical system if the battery
system polarity is reversed. Provides frequency lockout, load dump, glow plug operation, and
interfacing of engine body harnesses.
ROTARY SWITCH - When in START position, actuates starter solenoid through circuits 1lA and
744. When in RUN position, closes circuit 29A to activate instrument cluster gauges through circuit 27.
CIRCUIT 7A - Connects the starter negative terminal to engine ground while circuit 7E connects
shunt to engine ground.
STARTER SOLENOID - Actuates starter motor gear to crank vehicle engine.
27 *
l-30


Back to Top