POSITION TANKER CONTROLS - Continued
16
FLAMMABLE
NO SMOKING WITHIN 50 FE T
Figure 5.
BONDING AND GROUNDING
NOTE
•
Bonding is the process of electrically connecting two units to equalize
and form a path for any static potential that might develop during
fueling process. Grounding is the process of electrically connecting
single or bonded units to ground rods. This discharges into the earth
any static potential that might exist at the beginning of operation or
that might develop during the operation.
•
Both vehicles and equipment involved must be bonded and grounded
before performing fueling procedures.
•
If you use only one ground rod to ground both vehicles, you do not
need to bond.
1.
Connect SR1 and SR2 static cables (1) to grounding devices and vehicle being
serviced.
TM 9-2320-429-10
0084
0084-6