TM-9-2320-429-10

TRUCK, TANK, 8X8, M978

TECHNICAL MANUAL; OPERATOR'S MANUAL

JUNE 2009

  TM-9-2320-429-10 - Page 428 of 1096

FUEL SERVICING (DUST CAPS INSTALLED ON SERVICING HOSES) - Continued
NOTE
V8 REEL VALVE controls rate of fuel delivery when passenger side
servicing hose is used for fueling.
11.
Adjust V7 REEL VALVE (10) to control rate of fuel delivery through servicing hose (3).
Table 1.
V7 and V8 Reel Valve
Fueling Delivery Rates.
Position
Gallons per Mi-
nute
1, 2, 3, 4
105 ± 5
5
90 ± 5
6
75 ± 5
7
50 ± 5
8
15 ± 5
12.
Push PUMP ENGAGEMENT LEVER (11) forward.
13.
Set TC/THROTTLE CONTROL switch (12) up to ON position.
TM 9-2320-429-10
0087
0087-8


Back to Top