FUEL SERVICING (FUEL SERVICE NOZZLES INSTALLED ON SERVICING HOSES) -
Continued
29.
Pull back on PUMP ENGAGEMENT LEVER (11) until locked.
30.
Push MC MANUAL CONTROL EM VALVE (9) forward.
31.
Close V7 REEL VALVE (10).
32.
Remove over-wing nozzle (6) from reducer adapter (7).
O
N
S
VALVE
5
7
3
6
Figure 18.
NOTE
Reducer adapter is used with over-wing nozzle only. If over-wing nozzle
was not used, skip to Step (35).
33.
Remove reducer adapter (7) from servicing hose (3).
34.
Return over-wing nozzle (6) and reducer adapter (7) to stowage.
35.
Remove hand crank handle (21) from stowage.
TM 9-2320-429-10
0087
0087-21