WARNING
POLYURETHANE COATING (CARC)
Eye and hearing protection must be worn at all times when using
power tools for grinding, cutting, sawing, and drilling. Failure to do so
may result in injury to personnel. Chemical Agent Resistant Coating
(CARC) paint contains isocyanate which is highly irritating to skin and
respiratory system. High concentrations of isocyanate can produce
symptoms of itching and reddening of skin, a burning sensation in the
throat and nose, and watering of the eyes. In extreme concentrations,
isocyanate can cause cough, shortness of breath, pain during
respiration, increased sputum production, and chest tightness. First
aid for ingestion: do not induce vomiting. Seek immediate medical
attention. First aid for skin contact: remove contaminated clothing.
Wash skin thoroughly with soap and water. If symptoms persist, seek
medical attention. First aid for eye contact: flush with water for 15
minutes or until irritation subsides. If symptoms persist, seek medical
attention. First aid for inhalation: move to fresh air. If not breathing,
provide artificial respiration. If symptoms persist, seek medical
attention.
The following precautions must be taken whenever using CARC
paint:
Protective equipment (gloves, goggles, ventilation mask) must be
worn when using CARC paint.
NEVER cut CARC-coated materials without high-efficiency, air-
purifying respirators in use.
DO NOT grind or sand painted equipment without high-efficiency, air-
purifying respirators in use.
BE AWARE of CARC paint exposure symptoms; symptoms can
occur a few days after initial exposure. Seek medical help
immediately if symptoms are detected.
Use only in well-ventilated area. Check with local environmental
office for methods and locations approved for painting in accordance
with local and state environmental regulations.
Always use air line respirators when using CARC paint unless air
sampling shows exposure to be below standards. Use chemical
cartridge respirator if air sampling is below standards.