TM 9-2320-440-13&P
0138-2
0138
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
The THAAD hydraulic system operates at oil pressure up to 3,250 psi (22,409 kPa).
Never disconnect any hydraulic line or fitting without first dropping pressure to
zero. Failure to comply may result in serious injury or death to personnel.
NOTE
•
Note position of tees and elbows prior to removal to ensure proper installation.
•
Position drain pan under hydraulic lines and fittings being removed.
•
Tag and mark hydraulic lines prior to removal to ensure proper installation.
•
Cap and plug hydraulic lines upon removal.
2.
Remove hose (5) and preformed packing (6) from tee (7). Discard preformed packing.
3.
Remove hose (8) and preformed packing (9) from tee (7). Discard preformed packing.
4.
Remove hose (10) and preformed packing (11) from tee (12). Discard preformed packing.
5.
Remove hose (13) and preformed packing (14) from tee (12). Discard preformed packing.
6.
Remove tee (7) and preformed packing (15) from fitting (16). Discard preformed packing.
7.
Remove tee (12) and preformed packing (17) from control valve (4). Discard preformed packing.
THAAD0090