TM 9-2320-440-13&P
0060-7/(8 blank)
0060
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- .
10. Install battery box (4) on battery box support bracket (11) with four screws (15), washers (14), and
locknuts (13).
11. Install four screws (10) on battery box (4) and battery box support bracket (11) with four nuts (9).
12. Install two clips (12) on screws (13).
WARNING
Anti-corrosion compound is toxic. Use only in well-ventilated area. Use NIOSH/
MSHA-approved respirator with dual organic vapor/mist and particulate cartridge.
Do not get in eyes; wear chemical safety goggles and full face shield when using.
Avoid contact with skin and wear rubber or plastic, solvent-resistant gloves. In case
of contact, remove contaminated clothing and immediately wash area with soap
and water. If eyes are contacted, flush eyes with large amounts of water for at least
15 minutes and get immediate medical attention. If swallowed, do not induce
vomiting; contact a physician immediately. Failure to comply may result in injury or
death to personnel.
13. Apply solvent resistant sealant to four screws (10), two clips (12), four washers (14), and screws (15) on
inside of battery box (4).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install batteries (WP 0059).
END OF TASK
END OF WORK PACKAGE