WARNING SUMMARY
Dry-cleaning solvent PD-680 is both toxic and flammable. Avoid prolonged breathing of vapors
and avoid skin contact. Do not use near open flame or excessive heat. Flash point of solvent
is
138°F (59°C). Serious illness, injury, or loss of life could result from improper use.
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure
personnel and damage equipment. Refer to TM 9-247.
Do not operate the trailer with any burned out or missing lights. Not being seen could result in
injury topersonnel and damage to equipment.
All persons not involved in coupling operation must stand clear of towing vehicle and trailer to
prevent possible injury.
Wear protective goggles to prevent eye injury when opening air reservoir draincock. Move
away from air stream to prevent injuries.
Particles blown by compressed air are hazardous. Make certain that the airstream is directed
away from user and other personnel in the area. User must wear safety eye goggles or face
shield to prevent injury when using compressed air. Make certain that air stream is less than 30
psi.
Before performing any maintenance tasks on brake system, disconnect trailer air lines from
towing vehicle and open draincock to release air pressure from system. Serious injury may
result from failure to do so.
All parts of the brake assembly will be coated with dust from the brake linings. A
nose mask
should be worn whenever working on any brake assembly components.
The return spring inside the brake chamber is under heavy spring tension. The two halves
must be clamped together in a vise before removing the fastening devices that hold it
together. Failure to do so could result in serious injury.
Do not raise leveling leg assembly unless the trailer is coupled to a towing vehicle or is
securely supported on jack stands. The trailer may fall, causing injury to personnel.
b
Change 1