TM-9-2330-330-14-P

SEMITRAILER, FUEL TANKER: 5000-GALLON, FUEL-DISPENSING, AUTOMOTIVE, M969A3

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

NOVEMBER 2005

  TM-9-2330-330-14-P - Page 758 of 1116

TM 9-2330-330-14&P
0168 00-6
VAPOR INTEGRITY TEST—Continued
0168 00
CAUTION
Although an emergency valve leak does not constitute a
K stamp (indicating compliance with DOT 49CF180.407 (h))
failure if the leak is internal, proper emergency valve operator
function is required for safe operation.
8.
Close emergency valve A (25) and monitor gage (30) on regulator assembly (12).
9.
Wait 5 minutes to verify that pressure reading remains stable. If pressure drops more than 0.5 in.
wc on gage (30), go to step 10. If pressure remains at 17.5 to 18.5 in. wc, go to step 13.


Back to Top