TM 9-2330-334-13&P
ANTI-LOCK BRAKE SYSTEM (ABS) RELAY VALVE
0072 00
HARNESS REPLACEMENT - Continued
Change 1
0072 00-6
INSTALLATION – Continued
NOTE
All ABS relay valve cable clamps are installed the same way. One is shown.
4.
Position ABS relay valve cable (1) in clamp (5).
5.
Position clamp (5) on rail assembly (6) with bolt (4) and self-locking nut (3).
6.
Tighten self-locking nut (3) to 96-120 lb-in. (11-14 N·m).
7.
Perform the previous three steps on remaining clamps.