TM 9-2330-334-13&P
BUMP STOP AND EXTENSION REPLACEMENT - Continued
0104 00
Change 1
0104 00-4
INSTALLATION
1.
Position bump stop (2) on bump stop tube (10).
NOTE
Apply threadlocking compound to threads of screws prior to installation.
2.
Install four shims (9) and bump stop cap (8), on bump stop with two lockwashers (7) and screws
(6).
3.
Tighten two screws to 28-34 lb-in. (38-47 N·m).