TM 9-2350-238-34-1
1-10. EQUIPMENT DATA (CONT) .
f.
Radiators .
(1)
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 39.25 in. h x 24.00 in. w x 5.00 in. deep
(99.70 cm h x 60.96 cm w x 12.70 cm deep)
(2)
Coolant flow (each radiator) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.70 gpm (265 l/min)
(3)
Top tank temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.210 °F(99 °C)
(4)
Weight (each).
..........
. . . . . . . . . . . .
. . . . . .
.73 lb(33 kg )
g.
Coolant Fan .
(1)
Design and construction data :
(a)
Outside diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.27.0 in.(68.6cm)
(b)
Overall length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.15.0 in. (38.1 cm)
(c)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.120.0 lb(53.4 kg)
(2)
Direction of rotation (viewed from pulley end) . . . . . . . . . . . . . . . . . . . . . . . Clockwise
(3)
Direction of airflow . . . . . . . . . . . . . . . . . . . . .
Through fan, into engine compartment
(4)
Number of mounting holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
(5)
Bolt circle diameter . . . . . . . . . . . . . . . . .
.
. . . . . . . . . . . .
.25.75 in. (65.41 cm)
h.
Hydraulic Rotary Pump .
(1)
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. Dual Vane
(2)
Rate output pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.2000 psi (13,790 kPa)
(3)
Rated flow at 2000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.7.6 gpm(28.8 I/min)
(4)
Maximum operating rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.1350 rpm
l .
Lockout Cylinder .
(1)
Length :
(a)
Retracted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.25.94 in. (65.89 cm)
(b)
Extended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.35.47 in. (90.09 cm)
(2)
Outside diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.6.00 in. (15.24 cm)
(3)
Weight, dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.82 lb (37 kg)
(4)
Operating pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psi (1034kPa)