TM 9-2350-256-20-1
0063 00
CORRECTIVE ACTION –Continued
6.
Reconnect wire 419 to panel connector side of 15 A circuit breaker. Disconnect wire 419 from APU
FUEL SHUTOFF switch side of15 A circuitbreaker. Placered lead ofmultimeteron terminal of circuit
breaker and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, go to step 7. If voltage is not present, replace 15 A circuit breaker
(see WP 0438 00).
7.
Reconnect wire 419 to 15 A circuit breaker. Disconnect wire 419 from circuit breaker side of APU
FUEL SHUTOFF switch. Place red lead of multimeter in wire 419 and black lead to ground. Turn
MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step
8. If voltage is not present, repair/replace wire 419 of APU fuel shutoff lead assembly (see WP 0438
00).
0063 00-6