TM 9-2350-256-34
0083 00
19.
Remove screw (80), lockwasher (81), and plate (82) from chain case (83). Discard lockwasher.
20.
Using puller, remove sprocket (84) and chain (85).
21.
Remove key (86) and bushing (87).
NOTE
Remove APU from test stand and place on floor to remove generator.
22.
Back off nut (88), loosen screw (89), and disconnect clamp (90).
23.
Remove cotter pin (91), pin (92), generator clamp (93), and generator duct (94). Discard cotter pin.
0083 00-11