TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 417 of 761

TM 9-2350-261-10
TROUBLESHOOTING TABLE
0074 00
INITIAL SETUP:
Maintenance Level
Operator
ENGINE
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ENGINE DOES NOT
CRANK WHEN YOU
PRESS START SWITCH.
1.
Check to see if MASTER SWITCH is OFF.
Turn MASTER SWITCH to ON
(WP 0026 00).
2.
Check to see if range selector controller is
in N position.
Place range selector in N position
(WP 0026 00).
3.
Check to see if batteries are in good
condition.
Troubleshoot electrical system
(page 0074 00-15).
2.
ENGINE CRANKS BUT
DOES NOT START.
1.
Check to see if fuel cutoff control is pulled
out.
Push fuel cutoff control in
(WP 0026 00).
2.
Check to see if there is enough fuel in fuel
tanks.
Refuel carrier; M113A2, M1064,
and M1059 (WP 0030 00),
M577A2 and M1068
(WP 0031 00).
3.
Check to see if fuel tank manual shutoff
valve is closed.
Open fuel tank manual shutoff
valve (WP 0004 00).
4.
If temperature is colder than +40 F(+4 C),
check to see if AIR BOX HEATER switch
is ON.
Use air box heater (WP 0026 00).
5.
Check to see if there is water in the fuel.
Drain primary and secondary fuel
filters (WP 0090 00).
6.
Check to see if engine is getting enough
air. Check air cleaner restriction indicator
(WP 0004 00). If indicator shows only red in
the window, notify unit maintenance.
Clear intake grill of any debris.
If engine still does not start, notify
unit maintenance.
3.
ENGINE CRANKS BUT
DOES NOT START WHEN
THE TEMPERATURE IS
BELOW +40 F(+4 C)
AND AIR BOX HEATER IS
USED.
1.
Have unit maintenance check to see if air
box heater system is operating properly.
2.
Have unit maintenance check to see if air
box heater fuel and air lines and electrical
connections are tight.
Tighten any loose connections.
007400-1
º
º
º
º


Back to Top