TM 9-2350-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
7.
With engine running, remove dust caps from engine and transmission oil sampling valves.
8.
Open sampling valve on engine oil filter and drain a small amount of oil into a container to clear valve of grit and
contamination. (Properly dispose of container and oil upon completion of sample taking.) Fill sampling bottle to the
neck shoulder and seal it. Attach DD Form 2026 to sample bottle.
9.
Close oil sample valve and install dust cap.
10. Take oil sample from transmission in the same manner (Steps 7 - 9).
11. Stop engine (WP 0029 00).
12. Install driver’s power plant access panel (WP 0048 00) and secure carrier.
0075 00-6