TM 9-2350-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
CAUTION
Use only FRH hydraulic fluid. Do not
mix different types of fluid. Do NOT
overfill.
b.
Check ramp hydraulic fluid level with
ramp down and carrier on level ground.
Fluid level must be visible halfway up in
ramp hydraulic fluid level sight glass. To
add FRH, remove fill plug and preformed
packing from top of tank. Add FRH as
needed (Table 2, page 0075 00-8). Install
fill plug with new preformed packing.
Fluid is
not visible
half-way up
in sight glass.
Breather cap is
missing.
0075 00-66