TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 548 of 761

TM 9-2350-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
75
Weekly
Air Cleaner
WARNING
Failure to decontaminate and wear
protective clothing after NBC attack
could result in serious health hazards
to personnel. Do not service air cleaner
or vent system after NBC attack until
carrier has been decontaminated.
If NBC exposure is suspected, all
air filter medial should be handled
by personnel wearing protective
equipment. Consult your unit NBC
officer or NBC NCO for appropriate
handling or disposal instructions.
Unlatched hatch covers can swing and
injure personnel. Make sure hatches
are latched open or closed.
CAUTION
Operating carrier with air cleaner
missing or damaged can cause extensive
engine damage. Do not operate carrier
if air cleaner element is missing or door
or gasket is missing or damaged.
CAUTION
Do not drop or rap filter element when
cleaning it.
0075 00-100


Back to Top