TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 119 of 767

TM 9-2350-261-20-4
REPLACE STOWAGE HOOKS AND BRACKETS (M113A2 AND M1059
ONLY) — Continued
0656 00
INSTALLATION
1.
Install four brackets (11) on carrier. Secure with eight screws (10).
2.
Install two brackets (9) on carrier. Secure with eight washers (8) and screws (7).
3.
Install two brackets (5) on carrier. Secure with four screws (6).
4.
Install two hooks (4) in two brackets (5). Secure with two spacers (3), plates (2), and wing nuts (1). Deform last two
threads of hooks to retain wing nuts.
END OF TASK
0656 00-2