TM-9-2350-261-20-4

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 4 OF 4

  TM-9-2350-261-20-4 - Page 93 of 767

TM 9-2350-261-20-4
REPLACE COOLANT PUMP TO COOLANT HEATER WIRING HARNESS — Continued
0649 00
INSPECTION AND REPAIR
1.
Check wiring harness continuity. Check leads for frayed or broken insulation or damaged terminal lugs. Repair harness
as needed (WP 0312 00).
INSTALLATION
1.
Place wiring harness (1) on coolant pump (2). Install ground lead (3) and nut (4) on pump terminal (5).
2.
Install circuit 402B lead (6) and nut (7) on pump terminal (8).
3.
Install ground lead (3), new lockwasher (9), and new locknut (10) on coolant pump mount screw (11).
4.
Install circuit 402B lead (6) and screw (12) on terminal 4 (13) of terminal strip (14).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Start coolant heater (see your -10). Check that wiring harness is installed right. Turn heater off.
3.
Close power plant access door (see your -10).
4.
Raisetrimvane(seeyour-10)
.
END OF TASK
0649 00-2


Back to Top