TM-9-2350-261-34

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

  TM-9-2350-261-34 - Page 85 of 785

TM 9-2350-261-34
VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068 ONLY) — Continued
0011 00
4Y
1 .
A pply external sou rce of A C pow er to SICPS
carrier
.
See TM 11-7010-256-12&P.
2.
Measure voltage between XK2 relay socket terminal 1 (1)
and terminal block E4 post 1 (2). Repeat check for terminals
3 (3) and 7 (4) of XK2 relay socket.
3.
Does multimeter read 110 volts AC for each measurement?
4YN
1.
Replace XK2 relay (WP 0084 00).
2.
Verify no faults found.
001100-6