TM-9-2350-274-BD

M109/M110/M578 VEHICLES HOWITZER, MEDIUM, SELF-PROPELLED FULL-TRACKED

TECHNICAL MANUAL; OPERATORS, ORGANIZATIONAL DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

JANUARY 1984

  TM-9-2350-274-BD - Page 73 of 219

TM 9-2350-274-BD
FUEL SUPPLY SYSTEM
- Output adequate
-pumps . . . . . . . . . . . . . . . . . . . . . .
. go to para 4-7 or 4-8
-fuel filters . . . . . . . . . . . . . . . . . . . .
. go to para 4-13
- Output degraded
- Output severely
degraded with BDAR
- No Output
ENGINE ASSESSMENT
Combat
Self
Mission
Combat
Emergency
Recovery
Capable
Capable
Capable
Capable
Recover
X
X
X
X
X
X
X
1
X
X
1
X
X’ Use as towed firing platform only.
4-3. BDAR Procedure Index.
Para
Fuel Tank Substitute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-5
Fuel Pump Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-7
Fuel Pump Interchangeability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-8
Fuel Pump (In-Tank) Inoperative. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-9
Quick Disconnect Leak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-11
Fuel Filter Clogged or Frozen.
.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..4-13
4-2


Back to Top