DESCRIPTION AND USE OF OPERATOR’S CONTROLS AND INDICATORS — Continued
0004 00
Table 6. MASTER SWITCH PANEL
KEY
CONTROL OR INDICATOR
FUNCTION
MASTER SWITCH
Turns carrier electrical power on or off.
AUXILIARY POWER RECEPTACLE
Used with a slave cable to start carrier engine using an outside
power source.
NIGHT VISION PERISCOPE POWER
CABLE STOWAGE RECEPTACLE
Used to stow night vision periscope power cable when periscope is
not in use.
UTILITY OUTLET
Provides power for 24-volt accessories.
COMPARTMENT BLOWER ON-OFF
SWITCH (M577A3 AND M1068A3
ONLY)
Turn compartment blower on or off.
FUEL TANK SELECTOR SWITCH
(M577A3 AND M1068A3 ONLY)
Two position toggle switch allows drive to read fuel level in either
tank.
FRONT DOME LIGHT SWITCH
(M577A3 AND M1068A3 ONLY)
Controls the domelights.
0004 00-13