TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 304 of 889

TM 9-2350-277-10
OPERATE FIXED FIRE EXTINGUISHER SYSTEM
0031 00
THIS WORK PACKAGE COVERS:
Operate Fixed Fire Extinguisher (Outside) (page 0031 00-2).
Operate Fixed Fire Extinguisher (Inside) (page 0031 00-3).
INITIAL SETUP:
Maintenance Level
Operator
Personnel Required
Driver or soldier
References
TM 3-1040-285-10
Equipment Condition
Fire extinguisher installed and seal unbroken
WARNING
If CO2 is discharged into engine compartment while engine is running, engine exhaust may be
poisonous. Poisonous gas can injure you. Stop engine before you discharge CO2. If CO2 is
discharged while engine is running, do not breathe engine exhaust.
WARNING
Engine fan can blow away CO2 before fire is extinguished. Personnel can get burned.
Equipment can get damaged. Stop engine before you operate fire extinguisher.
NOTE
Notify unit maintenance after fixed fire extinguisher is discharged.
0031 00-1