TM 9-2350-277-10
OPERATE NBC KIT — Continued
0080 00
TURN NBC KIT ON IN CARRIER WITHOUT LITTER KIT
WARNING
Filters and masks of the NBC system will not protect you against carbon monoxide, ammonia,
acid, or solvent fumes. Be sure the carrier is properly ventilated. Do not let any filters of the
NBC system get wet. Water will destroy their ability to take the deadly chemical and biological
agents out of the air. Contaminated filters must be handled using adequate precautions and
must be disposed of by trained personnel. If it is very cold outside, there is danger of frostbitten
lungs from inhaling the cold air. Do not connect the hoses to your M42 mask canister until NBC
system has been operating at least 15 minutes with the heater turned on.
NOTE
For operation of M42 protective mask, refer to TM 3-4240-346-10.
1.
All crew members must put on their M42 protective mask. Adjust the mask.
2.
Remove spring clip from air intake openings on air purifier.
3.
Turn on heater to warm air coming into M42 mask by turning knob clockwise from OFF until light comes ON.
NOTE
Light may go on and off by itself during operation. This is normal; the light is lit only when
heating element is on.
4.
Adjusttodesiredwarmthbyturningknobclockwise to increase heat and counterclockwise to decrease heat.
0080 00-4
Change 4


Back to Top