TM 9-2350-277-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0090 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
10
Before
Fixed Fire
Extinguisher
DRIVER
WARNING
A fire can break out at any time.
Personnel could be killed or injured.
Equipment could be damaged. Make
sure all fire extinguishers are ready to
use before you operate carrier.
CAUTION
Inspect cylinder/bottle data to
ensure the latest hydrostatic test was
performed within the past 5 years. Any
bottle/cylinder beyond the test time
limit shall be declared unserviceable
and replaced.
a.
Inspect fire extinguisher cylinder data
plate to ensure that a hydrostatic test has
been performed within the past 5 years.
Faulty extinguishers or those beyond the
test time limit (5 years) shall be declared
unserviceable and replaced.
If cylinder/
bottles are
overdue for
a hydrostatic
test.
b.
Check fixed extinguisher control seal.
Extinguisher
missing.
0090 00-22
Change 5