TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 616 of 889

TM 9-2350-277-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0090 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
40
During
Mortar Fire
Control System
(MFCS)
(M1064A3 and
M577A3)
DRIVER/GUNNER/COMMANDER
a.
See TM 9-1220-248-10 to conduct PMCS
for M1064A3 or TM 9-1220-249-10 to
conduct PMCS for M577A3.
Fault listed in
“Equipment
Not Ready/
Available If:”
column of
MFCS TM.
41
During
Generator Set
(M577A3 and
M1068A3)
CREWMEMBER
a.
See TM 5-6115-596-14 for PMCS
procedures.
Fault listed in
“Equipment
Not Ready/
Available If:”
column of
generator TM.
42
During
Auxiliary Power
Unit (APU)
(M577A3 and
M1068A3)
CREWMEMBER
a.
See TM 9-6115-664-13&P for PMCS
procedures.
Fault listed in
“Equipment
Not Ready/
Available If:”
column of
APU TM.
43
During
Seatbelts
COMMANDER
a.
Ensure all personnel are buckled in their
seats. Personnel sitting in open hatch
area must not expose more than head and
shoulders to name tag level, except when
firing weapons.
Missing, worn,
torn, or frayed
belt. Buckle
that will not
lock and/or
unlock.
0090 00-61
Change 5


Back to Top