TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 681 of 889

TM 9-2350-277-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0090 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
96
Weekly
Slave Receptacle,
Cable, and
Generator
NOTE
Make sure slave receptacle cap on
M577A3 and M1068A3 is secure.
Report damage to unit maintenance.
a.
Check receptacle and cable for damage,
burn-out condition, and corrosion.
Receptacle
or cable
damaged,
burnt-out, or
missing.
b.
Check that volts are in the green zone of
voltmeter.
Voltage meter
not in the green
zone.
c.
Check generator set for mud, dirt, and
excess oil and grease. Clean as required.
Generator set
missing or
inoperative.
0090 00-126
Change 5


Back to Top