TM-9-2350-277-10

CARRIER, M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; OPERATOR’S MANUAL

  TM-9-2350-277-10 - Page 95 of 889

TM 9-2350-277-10
EQUIPMENT DESCRIPTION — Continued
0002 00
BILGE PUMPS
There are two bilge pumps. The forward pump is in the left front corner of the power plant compartment. The rear pump
is under the floor plates on the right rear side of the carrier. When turned on, they remove water that may leak in during
fording operations.
RAMP
The ramp is located at the rear of the carrier to permit rapid entry and exit.
FUEL TANK EXTERNAL
The external fuel tanks for the M113A3, M1059A3, M58, and M1064A3 carriers are mounted on the left and right rear
corners of the carrier. Both tanks supply diesel fuel to the engine through a single main fuel line.
0002 00-34
Change 5


Back to Top