TM 9-2350-277-20-1
FRONT AND/OR REAR BILGE PUMP(S) AND/OR LIGHTS DON’T WORK—Continued
0080 00
B4Y
1.
Check continuity between plug 450 A (1) to 450 A lead end at
bus bar (2) for rear pump; or plug 450 C (3) to 450 C lead end at
bus bar (4) for front pump.
2.
Is there continuity?
YES
NO
B4YN
1.
Replace lead 10861710 (front),
(WP 0270 00), or replace lead
10861711 (rear), (WP 0270 00).
2.
Install bilge pump leads.
3.
Verify no faults found.
B5Y
1.
Remove instrument panel for access (WP 0295 00).
2.
Remove plug 450 B (1) and plug 452 B (2) (front) or plug 450 (3)
and 451 A (4) (rear) from bilge pump switch (5).
3.
Check continuity between bilge pump switch jacks with BILGE
PUMPS switch on.
4.
Is there continuity?
YES
NO
B5YN
1.
Install master switch panel
(WP 0260 00).
2.
Replace bilge pump switch
(WP 0281 00).
3.
Verify no faults found.
B6Y
1.
Repair harness 12268797 circuit 450 or 450B (WP 0382 00).
2.
Verify no faults found.
0080 00-4