NO AC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)—Continued
0091 00
T
1.
Remove cable W32, plug P15 (1) from Power Control Enclosure
jack J32 (2).
2.
Apply AC power to SICPS
system, TM 11-7010-256-12&P.
3.
Measure voltage between socket A and socket B of jack J32 (2)
and then between socket A and socket C.
4.
Does multimeter read 110 volts AC or more for each
measurement?
YES
NO
GO TO
BY
(PAGE 0091 00-4)
0091 00-2