6Y
1.
Turn OFF AC and DC Power (TM 11-7010-256-12&P).
2.
Remove 12 screws (1), lockwashers (2), and cover (3) from
Power Control Enclosure (4). Discard lockwashers.
3.
Measure resistance between terminal 2 (5) of circuit breaker CB5
(6) and AC HIGH terminal (7) of power supply PS2 (8).
4.
Does multimeter read 0 ohms?
YES
NO
6YN
1.
Faulty circuit 10A. Beyond unit
maintenance repair.
2.
Notify supervisor.