INVERTER POWER-UP FAILURE (M1068A3 ONLY)
0109 01
INITIAL SETUP:
Maintenance Level
Unit
Personnel Required
Mechanic
References
TM 9-2350-277-10
Equipment Condition
Engine stopped (TM 9-2350-277-10)
Carrier blocked (TM 9-2350-277-10)
Inverter control switch in the OFF position
NOTE
During power-up, the only indication the inverters are on is the sound of their turbo fans.
T
1.
Turn OFF all AC and DC circuit breakers. See TM
9-2350-277-10.
2.
Turn MASTER switch ON. See TM 9-2350-277-10.
3.
Turn INVERTER CONTROL switch to Primary A.
4.
Is inverter control LED A ON?
TN
1.
Faulty inverter A. Beyond unit
maintenance repair.
2.
Notify supervisor.
Y
1.
Is inverter control lamp B off?
2YN
1.
Verify no faults found.
2Y
1.
Turn INVERTER CONTROL switch to Primary B.
2.
Are inverter control lamps A and B off?
3YN
1.
Verify no faults found.
3Y
1.
Faulty inverter B. Beyond unit maintenance repair.
2.
Notify supervisor.