TM 9-2350-277-20-1
MSD/ICE TEST 83 GENERATOR FIELD VOLTAGE DIAGNOSTIC
TROUBLESHOOTING — Continued
0152 00
CY
1.
Remove W1 P2 (1) from MSD/ICE distribution box jack J2 (2).
2.
Measure resistance between MSD/ICE distribution box jack J2
(2), pins M (3) and O (4). MSD should read 0 ohms.
3.
Does MSD indicate a fault?
CYN
1.
Faulty W1 cable. Beyond unit
maintenance repair.
2.
Notify supervisor.
C2Y
1.
Remove harness 12354593 P1 (1) from MSD/ICE
distribution box jack J1 (2).
2.
Measure resistance between 12354593 P1 (1), pins f (3)
andE(4)
.MSDshouldread0ohms
.
3.
Does MSD indicate a fault?
C2YN
1.
Replace MSD/ICE distribution
box (WP 0874 00, WP 0875 00,
or WP 0877 00).
2.
Verify no faults found.
015200-5
Change 5