TM 9-2350-277-20-3
REPLACE REAR UTILITY RECEPTACLE CIRCUIT BREAKERS (M577A3 AND M1068A3
ONLY) — Continued
0276 00
2.
Disconnect circuit 10 lead (6) and circuit 37A lead (7) from left circuit breaker (8).
3.
Disconnect circuit 38B lead (9) and circuit 10 lead (10) from right circuit breaker (11).
4.
Remove four nuts (12), screws (13), and circuit breakers (8) and (11) from distribution box (5).
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Inspect gasket on flange of distribution box. Replace if damaged.
0276 00-2