TM-9-2350-277-20-3

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 3 OF 6

  TM-9-2350-277-20-3 - Page 673 of 941

TM 9-2350-277-20-3
REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE GROUND LEAD (M113A3,
M1059A3, M1064A3, AND M58 ONLY) — Continued
0379 00
2.
Remove screw (6), lockwasher (7), and ground lead (8) from negative post (9) of auxiliary power receptacle (10). Do not
discard lockwasher.
3.
Remove locknut (11), washer (12), lead (13), ground lead (8), and lockwasher (14) from instrument panel hull strut
mount (15). Discard locknut and lockwasher.
4.
Remove ground lead (1) and grommet (2) from master switch panel (3). Discard grommet.
0379 00-2
Change 2


Back to Top