TM-9-2350-277-20-5

CARRIER M113A3, M577A3, M1059A3, M1064A3, M1068A3 AND M58

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 5 OF 6

  TM-9-2350-277-20-5 - Page 446 of 1047

TM 9-2350-277-20-5
REPAIR COOLANT HEATER CONTROL BOX — Continued
0737 00
3.
Remove RUN-OFF-START switch from control box:
a.
Remove six screws (1), lockwashers (2), jumper 15-17 (3), jumper 13-20 (4), lead 20-C (5), lead 14-A (6), jumper
21-18 (7), jumper 21-14 (8), lead 19-2 (9), and lead 19-E (10) from RUN-OFF-START switch (11).
b.
Remove two screws (12) and RUN-OFF-START switch (11) from control box (13).
0737 00-3


Back to Top