REPL ACE NBC HEAT ER WIRING HARNESS ( M 577A3 O NLY) -- Co n t in u e d
0808 00
12. Conne c t wi ri ng ha rne ss (5) t o c ont rol box (7).
13. Install ground lead (10) onto control box (7) with two new lockwashers (9) and screw (8).
14. Inst a l l four sc re ws (1), ne w l oc kwa she rs (2), four c l a m ps (3), and straps (4) on we l dnut s with wiring harness (5) and cable
11. Inst a l l ground l e a d (15),
l oc kwa she r (12),
washer (13), a nd sc re w (11)
, and new locknut (14) on frame (16).
10. Install new str
aps (17) alon
g ground lead (15) and adjacent wiring harness (5).
FOLLOW--THROUGH STEPS
1.
Master switch panel assembly installed (WP 0261 007).
2.
Connect battery ground lead (WP 0338 00).
END OF TASK
Change 2
0808 00 -- 5/6 blank
8. Connect cable connector (20) onto air purifier (18).
9. Remove screw (19) on air purifier (18).
Install ground lead (15) with screw (19) on air purifier (18).
NOTE
Le ad (15) may be mounted to either front or back side of frame (16).