TM 9-2350-277-20-6
REPLACE AC POWER EXTENSION BOX A6 AND DC POWER EXTENSION
BOX A9 AND MOUNT (M1068A3 ONLY)
0834 00
THIS WORK PACKAGE COVERS:
Removal (page 0834 00-1).
Installation (page 0834 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Locknut (8)
Personnel Required
Power-Generation Equipment Repairer 52D10
References
See your -10
TM 11-7010-256-12&P
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
All external power disconnected
(TM 11-7010-256-12&P)
Battery ground lead disconnected (WP 0338 00)
REMOVAL
1.
Disconnect UPS cable W42 (1) from connector (2) on DC power extension box (3).
0834 00-1