TM 9-2350-277-20-6
REPLACE COMMANDER’S INTERCOMMUNICATION SET CABLE (M58 ONLY) —
Continued
0893 00
INSTALLATION
1.
Connect cable connector (7) to commander’s intercom box J801 (8).
2.
Connect cable connector (5) to amplifier J504 (6).
3.
Install clamp (3), new lockwasher (2), and screw (1) on cable (4).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00).
2.
Raise and lock ramp (see your -10).
END OF TASK
0893 00-2