TM 9-2350-277-34
REPAIR POWER PLANT DOOR HINGE
0047 00
THIS WORK PACKAGE COVERS:
Removal (page 0047 00-1).
Installation (page 0047 00-3).
INITIAL SETUP:
Maintenance Level
Direct Support
Tools and Special Tools
Metal Worker’s Tool Kit (WP 0120 00, Item 63)
Trailer Mounted Welding Shop (WP 0120 00, Item 69)
Sander Spindle Adapter (WP 0120 00, Item 1)
Welder’s Gloves (WP 0120 00, Item 18)
Industrial Goggles (WP 0120 00, Item 19)
Welder’s Helmet (WP 0120 00, Item 21)
Electric Disc Sander (WP 0120 00, Item 46)
Arc Welding Machine (WP 0120 00, Item 68)
Materials/Parts
Enamel (WP 0122 00, Item 12)
Welding electrode (WP 0122 00, Item 35)
Personnel Required
Metal Worker 44B10
References
See your -20
TM 43-0139
TM 9-237
Equipment Condition
Power plant door removed (see your -20)
Power plant door seal removed from hinge (see your -20)
REMOVAL
1.
Remove remaining portion of damaged hinge (1) or (2) from door (3).
WARNING
Metal chips and grinding dust can cause injury. Wear goggles and gloves.
2.
Use a machinist hammer and a cold chisel to chip off remaining part of bad hinge (1) or (2) from door (3).
0047 00-1